摘要:系统运维 一、keepalive实现双主:1.1实验准备2台主机地址分别为:172.20.10.9,172.20.10.10,vip1为172.20.10.10,vip2为172.20.10.111.2通
系统运维
一、keepalive实现双主:
1.1实验准备
2台主机地址分别为:172.20.10.9,172.20.10.10,
vip1为172.20.10.10,vip2为172.20.10.11
1.2通知脚本:
[root@node5 /]# vim /etc/keepalived/notify.sh
#!/bin/bash
contact=\'root@localhost\'
notify() {
local mailsubject=$(hostname) to be $1, vip floating
local mailbody=$(date +\'%F %T\'): vrrp transition, $(hostname) changed to be $1
echo $mailbody | mail -s $mailsubject $contact
}
case $1 in
master)
notify master
;;
backup)
notify backup
;;
fault)
notify fault
;;
*)
echo Usage: $(basename $0) {master|backup|fault}
exit 1
;;
esac
1.3配置node5为vip1地址的主节点,vip2地址的备节点
[root@node5 ~]# vim /etc/keepalived/keepalived.conf
! Configuration File for keepalived
global_defs {
notification_email {
root@localhost
}
notification_email_from keepalived@localhost
smtp_server 127.0.0.1
smtp_connect_timeout 30
router_id node5
vrrp_mcast_group4 224.0.100.19
}
vrrp_instance VI_1 {
state MASTER
interface ens33
virtual_router_id 51
priority 100
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
172.20.10.10/28 dev ens33 label ens33:0
}
notify_master /etc/keepalived/notify.sh master
notify_backup /etc/keepalived/notify.sh backup
notify_fault /etc/keepalived/notify.sh fault
}
vrrp_instance VI_2 {
state BACKUP
interface ens33
virtual_router_id 52
priority 98
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
172.20.10.11/28 dev ens33 label ens33:1
}
notify_master /etc/keepalived/notify.sh master
notify_backup /etc/keepalived/notify.sh backup
notify_fault /etc/keepalived/notify.sh fault
}
1.4配置node6为vip1地址的备节点,vip2地址的主节点
[root@node6 ~]# vim /etc/keepalived/keepalived.conf
! Configuration File for keepalived
global_defs {
notification_email {
root@localhost
}
notification_email_from keepalived@localhost
smtp_server 127.0.0.1
smtp_connect_timeout 30
router_id node5
vrrp_mcast_group4 224.0.100.19
}
vrrp_instance VI_1 {
state BACKUP
interface ens33
virtual_router_id 51
priority 98
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
172.20.10.10/28 dev ens33 label ens33:0
}
notify_master /etc/keepalived/notify.sh master
notify_backup /etc/keepalived/notify.sh backup
notify_fault /etc/keepalived/notify.sh fault
}
vrrp_instance VI_2 {
state MASTER
interface ens33
virtual_router_id 52
priority 100
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
172.20.10.11/28 dev ens33 label ens33:1
}
notify_master /etc/keepalived/notify.sh master
notify_backup /etc/keepalived/notify.sh backup
notify_fault /etc/keepalived/notify.sh fault
}
1.5验证:
(1)先开启node6节点的keepalived服务,查看IP地址,状态:
2个VIP地址都在node6节点上:
(2)再开启node5节点keepalived服务,查看IP地址和状态:
VIP1地址已经飘到了node5节点上了
二,Nginx+Keepalived实现站点高可用
2.1实验准备:
2台主机:node5地址为172.20.10.9,node6的节点为172.20.10.8
vip地址为172.20.10.10
2.2nginx配置
(1)node5节点
[root@node5 ~]# yum install nginx -y
[root@node5 /]# vim /usr/share/nginx/html/index.html
node5 web page
[root@node5 ~]# systemctl start nginx
(2)node6节点
[root@node6 /]# yum install -y nginx
[root@node6 /]# vim /usr/share/nginx/html/index.html
node6 web page
[root@node6 ~]# systemctl start nginx
2.3配置node5为vip的主节点,配置检查nginx的监控脚本:
[root@node5 /]# vim /etc/keepalived/keepalived.conf
! Configuration File for keepalived
global_defs {
notification_email {
root@localhost
}
notification_email_from keepalived@localhost
smtp_server 127.0.0.1
smtp_connect_timeout 30
router_id node5
vrrp_mcast_group4 224.0.100.19
}
vrrp_script chk_nginx {
script /usr/bin/killall -0 nginx && exit 0 || exit 1
interval 1
weight -5
fall 2
rise 1
}
vrrp_instance VI_1 {
state MASTER
interface ens33
virtual_router_id 51
priority 100
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
172.20.10.10/28 dev ens33 label ens33:0
}
track_script {
chk_nginx
}
track_interface {
ens33
}
notify_master /etc/keepalived/notify.sh master
notify_backup /etc/keepalived/notify.sh backup
notify_fault /etc/keepalived/notify.sh fault
}
[root@node5 keepalived]# systemctl start keepalived
2.4配置node6为vip的备节点,配置检查nginx的监控脚本:
[root@node6 /]# vim /etc/keepalived/keepalived.conf
! Configuration File for keepalived
global_defs {
notification_email {
root@localhost
}
notification_email_from keepalived@localhost
smtp_server 127.0.0.1
smtp_connect_timeout 30
router_id node5
vrrp_mcast_group4 224.0.100.19
}
vrrp_script chk_nginx {
script /usr/bin/killall -0 nginx && exit 0 || exit 1
interval 1
weight -5
fall 2
rise 1
}
vrrp_instance VI_1 {
state BACKUP
interface ens33
virtual_router_id 51
priority 98
advert_int 1
authentication {
auth_type PASS
auth_pass 1111
}
virtual_ipaddress {
172.20.10.10/28 dev ens33 label ens33:0
}
track_script {
chk_nginx
}
track_interface {
ens33
}
notify_master /etc/keepalived/notify.sh master
notify_backup /etc/keepalived/notify.sh backup
notify_fault /etc/keepalived/notify.sh fault
}
[root@node6 html]# systemctl start keepalived
3.验证:
3.1当服务都正常时,vip地址在node5节点上,测试访问172.20.10.10的情况:
3.2当down掉node5节点上nginx服务时,观察vip地址和其访问情况:
vip地址飘到node6节点上,curl172.20.10.10,则访问的时node6节点
3.3当恢复node5节点上nginx服务时,vip地址飘到node5节点上,访问172.20.10.10则是node5上nginx
相关文章推荐
虚拟主机的专业参数,分别都是什么意思?2022-09-09
中非域名注册规则是怎样的?注册域名有什么用处? 2022-01-10
HostEase新年活动促销 美国/香港主机全场低至五折2021-12-28
HostGator下载完整备份教程分享2021-12-28
Flink中有界数据与无界数据的示例分析2021-12-28